Practice 8 XT 2000 exam questions with instant feedback and cited explanations.
Before discharging effluent containing XT 2000 into sewer systems, what action must be taken?
Answer: The label states not to discharge effluent to sewer systems without previously notifying the local sewage treatment plant authority.
Which target pest is XT 2000 specifically indicated to control via the described application method?
Answer: The label facts explicitly list Structural Drywood Termite as the target pest.
What is the maximum duration recommended for injecting the product into drilled holes?
Answer: The label instructions specify to inject for up to one minute.
When applying XT 2000 to infested wood, what is the recommended pattern and spacing for drilling holes?
Answer: The label instructions state to use a 'W' pattern at 3"-5" intervals.
Which of the following is a required component of the PPE for all pesticide handlers using XT 2000?
Answer: The PPE section requires long-sleeved coveralls worn over a minimum of a short-sleeved shirt and short pants.
According to the label restrictions, what must a technician avoid when drilling into wood for treatment?
Answer: The label explicitly states to avoid electrical wiring and plumbing when drilling.
What is the restriction regarding reapplication of XT 2000 to the same area?
Answer: The label restrictions state: 'Do not reapply again to same area within one year.'
When drilling holes into 'kick-outs' to intersect galleries, what size drill bit should be used?
Answer: The label instructions specify to drill 7/64" holes into 'kick-outs'.